How Good Are the Sleep Apnea Questionnaires, Really?
A meta-analysis of 108 studies and 47,989 people graded the four screening questionnaires. The best one flags almost everyone with severe apnea and is wrong about two thirds of the people it flags. The most widely used one is the worst of the four.
Before anyone puts a sensor on you, somebody hands you a questionnaire. It will be one of four, and the score it produces will shape whether you get tested, how quickly, and sometimes whether you are taken seriously at all.
So it is worth knowing how well they work. The answer has been measured properly, and it is more interesting than either "they work" or "they don't."
The four questionnaires
STOP-BANG — eight yes/no items: Snoring, Tiredness, Observed apneas, Pressure (hypertension), BMI, Age, Neck circumference, Gender. Score out of 8. It is the one our sleep apnea risk check is built on.
STOP — the first four of those, without the physical measurements.
The Berlin questionnaire — three categories covering snoring, daytime sleepiness, and hypertension or obesity.
The Epworth Sleepiness Scale — eight everyday situations, each rated 0 to 3 for how likely you are to doze. Score out of 24, with above 10 conventionally abnormal. This is the one you have almost certainly filled in, and the one our daytime sleepiness check uses.
Note what the fourth one is doing differently. Three of these ask about apnea risk factors. The Epworth asks about sleepiness, which is a symptom that apnea often causes and many other things cause too. That distinction turns out to matter enormously.
What the numbers say
A bivariate meta-analysis in Sleep Medicine Reviews pooled 108 studies covering 47,989 participants and estimated how each tool performs at three severity thresholds. These are the figures.
For detecting mild apnea or worse (AHI ≥ 5 events/hour):
| Tool | Sensitivity | Specificity |
|---|---|---|
| STOP-BANG | 88% | 42% |
| STOP | 87% | 42% |
| Berlin | 76% | 59% |
| Epworth | 54% | 65% |
For detecting severe apnea (AHI ≥ 30):
| Tool | Sensitivity | Specificity |
|---|---|---|
| STOP-BANG | 93% | 35% |
| STOP | 90% | 28% |
| Berlin | 84% | 38% |
| Epworth | 58% | 60% |
STOP-BANG was significantly better than the other three on both sensitivity and diagnostic odds ratio at every severity level. It was also significantly worse than the Epworth on specificity.
What those numbers actually mean for you
Two things, and most people take away the wrong one.
A high STOP-BANG score does not mean you have sleep apnea. Specificity of 35% at the severe threshold means that of the people without severe apnea, only about a third are correctly cleared — the other two thirds screen positive anyway. The questionnaire is built to over-call. It asks whether you are male, over 50, with a BMI over 35 and high blood pressure, and an enormous number of people who do not have apnea answer yes to several of those.
A low STOP-BANG score is genuinely informative. Sensitivity of 93% for severe apnea means it misses very few serious cases. That is the job it is designed for and the job it does well. A screening tool is supposed to be a wide net, and this is the best of the four at being one.
So read your score in that direction. High is a reason to get tested. Low is reasonable reassurance. Neither is a diagnosis.
The Epworth is the weakest of the four, and the one you will be given
This is the finding worth carrying away, because the Epworth Sleepiness Scale is everywhere — in clinics, in referral forms, in every online quiz — and across all three severity thresholds it had the lowest sensitivity of the four tools tested: 54% for mild, 58% for severe.
For detecting apnea, that is close to a coin flip.
The reason is not that the questionnaire is badly designed. It is that it measures something else. Plenty of people have significant obstructive sleep apnea and do not feel sleepy — they feel fine, or they feel tired in a way that does not involve dozing off, or they have simply recalibrated over fifteen years. The Epworth cannot see them, because there is nothing for it to see.
The practical consequence: a normal Epworth score does not rule out sleep apnea, and if you have been reassured on that basis while having witnessed apneas or morning headaches, the reassurance was not well founded. Sleepiness and fatigue are not the same thing, and apnea produces both and sometimes neither.
What the Epworth is genuinely good for is tracking change in one person over time. It is the standard outcome measure in treatment trials for exactly that reason, and it is how residual sleepiness on CPAP gets quantified. Your score before treatment against your score after is a meaningful comparison. Your score against a diagnostic threshold is not.
The guideline position
The American Academy of Sleep Medicine's clinical practice guideline for diagnosing adult obstructive sleep apnea addresses this directly, with a strong recommendation — the highest grade it issues — that clinical tools, questionnaires and prediction algorithms not be used to diagnose obstructive sleep apnea in adults in the absence of polysomnography or home sleep apnea testing.
That is not a criticism of the questionnaires. It is a statement about what category of thing they are. They decide who gets tested. They do not decide who has the condition.
Evidence tier 1 for STOP-BANG as a screening instrument, on the strength of a 48,000-participant meta-analysis and consistent guideline endorsement of screening. Tier 3 for any of them as a diagnosis, which is the guideline's own position. How we grade evidence.
How to use your score
If you screen positive, bring the score, not the conclusion. "I scored 6 on STOP-BANG and my partner has seen me stop breathing" is a sentence that moves an appointment forward. It is concrete, it is the language the clinician already uses, and it does not require them to take your self-diagnosis on trust. What to tell the sleep doctor.
Pair it with something objective. A questionnaire plus an overnight recording of your own snoring, or an overnight oxygen trace, is a much stronger case than a questionnaire alone — and the oxygen trace has the same one-way logic, informative when clearly abnormal and weak when clean. Recording your snoring, and what a pulse oximeter establishes.
If you screen negative but you have the symptoms, keep going. Especially on an Epworth. The symptoms are better evidence than the score, and the measured sensitivity says so.
Do not use a score to rule yourself out of a test you otherwise want. That is the only way these tools cause real harm, and it is the most common.
The apnea line
A questionnaire is a triage instrument and nothing more. No score on this page diagnoses anything, and no consumer product treats obstructive sleep apnea.
Witnessed breathing pauses, gasping or choking arousals, waking unrefreshed after a full night, morning headaches, or sleepiness that more sleep does not fix — those point at a test whatever any questionnaire returned. How to tell snoring from apnea, and what a home test involves.